Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.859
Filtrar
1.
Sci Adv ; 10(16): eadj0268, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38640247

RESUMO

Continuous monitoring of biomarkers at locations adjacent to targeted internal organs can provide actionable information about postoperative status beyond conventional diagnostic methods. As an example, changes in pH in the intra-abdominal space after gastric surgeries can serve as direct indicators of potentially life-threatening leakage events, in contrast to symptomatic reactions that may delay treatment. Here, we report a bioresorbable, wireless, passive sensor that addresses this clinical need, designed to locally monitor pH for early detection of gastric leakage. A pH-responsive hydrogel serves as a transducer that couples to a mechanically optimized inductor-capacitor circuit for wireless readout. This platform enables real-time monitoring of pH with fast response time (within 1 hour) over a clinically relevant period (up to 7 days) and timely detection of simulated gastric leaks in animal models. These concepts have broad potential applications for temporary sensing of relevant biomarkers during critical risk periods following diverse types of surgeries.


Assuntos
Implantes Absorvíveis , Transdutores , Animais , Tecnologia sem Fio , Concentração de Íons de Hidrogênio , Biomarcadores
2.
PLoS One ; 19(4): e0301073, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38598499

RESUMO

Router nodes placement (RNP) is an important issue in the design and implementation of wireless mesh networks (WMN). This is known as an P-hard problem, which cannot be solved using conventional algorithms. Consequently, approximate optimization strategies are commonly used to solve this problem. With heavy node density and wide-area WMNs, solving the RNP problem using approximation algorithms often faces many difficulties, therefore, a more effective solution is necessary. This motivated us to conduct this work. We propose a new method for solving the RNP problem using reinforcement learning (RL). The RNP problem is modeled as an RL model with environment, agent, action, and reward are equivalent to the network system, routers, coordinate adjustment, and connectivity of the RNP problem, respectively. To the best of our knowledge, this is the first study that applies RL to solve the RNP problem. The experimental results showed that the proposed method increased the network connectivity by up to 22.73% compared to the most recent methods.


Assuntos
Aprendizado de Máquina , Tecnologia sem Fio , Algoritmos
3.
Sci Adv ; 10(14): eadn3784, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38569040

RESUMO

Conventional power-integrated wireless neural recording devices suffer from bulky, rigid batteries in head-mounted configurations, hindering the precise interpretation of the subject's natural behaviors. These power sources also pose risks of material leakage and overheating. We present the direct printing of a power-integrated wireless neural recording system that seamlessly conforms to the cranium. A quasi-solid-state Zn-ion microbattery was 3D-printed as a built-in power source geometrically synchronized to the shape of a mouse skull. Soft deep-brain neural probes, interconnections, and auxiliary electronics were also printed using liquid metals on the cranium with high resolutions. In vivo studies using mice demonstrated the reliability and biocompatibility of this wireless neural recording system, enabling the monitoring of neural activities across extensive brain regions without notable heat generation. This all-printed neural interface system revolutionizes brain research, providing bio-conformable, customizable configurations for improved data quality and naturalistic experimentation.


Assuntos
Encéfalo , Cabeça , Animais , Camundongos , Reprodutibilidade dos Testes , Crânio , Eletrônica , Tecnologia sem Fio
4.
PLoS One ; 19(4): e0301470, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38578810

RESUMO

In wireless sensor networks, the implementation of clustering and routing protocols has been crucial in prolonging the network's operational duration by conserving energy. However, the challenge persists in efficiently optimizing energy usage to maximize the network's longevity. This paper presents CHHFO, a new protocol that combines a fuzzy logic system with the collaborative Harris Hawks optimization algorithm to enhance the lifetime of networks. The fuzzy logic system utilizes descriptors like remaining energy, distance from the base station, and the number of neighboring nodes to designate each cluster head and establish optimal clusters, thereby alleviating potential hot spots. Moreover, the Collaborative Harris Hawks Optimization algorithm employs an inventive coding mechanism to choose the optimal relay cluster head for data transmission. According to the results, the network throughput, HHOCFR is 8.76%, 11.73%, 8.64% higher than HHO-UCRA, IHHO-F, and EFCR. In addition, he energy consumption of HHOCFR is lower than HHO-UCRA, IHHO-F, and EFCR by 0.88%, 39.79%, 34.25%, respectively.


Assuntos
Falconiformes , Lógica Fuzzy , Animais , Tecnologia sem Fio , Redes de Comunicação de Computadores , Algoritmos
5.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 173-178, 2024 Mar 30.
Artigo em Chinês | MEDLINE | ID: mdl-38605617

RESUMO

A wireless wearable sleep monitoring system based on EEG signals is developed. The collected EEG signals are wirelessly sent to the PC or mobile phone Bluetooth APP for real-time display. The system is small in size, low in power consumption, and light in weight. It can be worn on the patient's forehead and is comfortable. It can be applied to home sleep monitoring scenarios and has good application value. The key performance indicators of the system are compared with the industry-related medical device measurement standards, and the measurement results are better than the special standards.


Assuntos
Telefone Celular , Dispositivos Eletrônicos Vestíveis , Humanos , Polissonografia , Eletrocardiografia , Tecnologia sem Fio , Eletroencefalografia
6.
Sci Adv ; 10(12): eadm9314, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38507494

RESUMO

Implantable sensors can directly interface with various organs for precise evaluation of health status. However, extracting signals from such sensors mainly requires transcutaneous wires, integrated circuit chips, or cumbersome readout equipment, which increases the risks of infection, reduces biocompatibility, or limits portability. Here, we develop a set of millimeter-scale, chip-less, and battery-less magnetic implants paired with a fully integrated wearable device for measuring biophysical and biochemical signals. The wearable device can induce a large amplitude damped vibration of the magnetic implants and capture their subsequent motions wirelessly. These motions reflect the biophysical conditions surrounding the implants and the concentration of a specific biochemical depending on the surface modification. Experiments in rat models demonstrate the capabilities of measuring cerebrospinal fluid (CSF) viscosity, intracranial pressure, and CSF glucose levels. This miniaturized system opens the possibility for continuous, wireless monitoring of a wide range of biophysical and biochemical conditions within the living organism.


Assuntos
Dispositivos Eletrônicos Vestíveis , Tecnologia sem Fio , Animais , Ratos , Próteses e Implantes , Fenômenos Físicos , Fenômenos Magnéticos
7.
Nanoscale ; 16(15): 7264-7286, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38470428

RESUMO

The rapid development of wearable sensing devices and artificial intelligence has enabled portable and wireless tracking of human health, fulfilling the promise of digitalized healthcare applications. To achieve versatile design and integration of multi-functional modules including sensors and data transmission units onto various flexible platforms, printable technologies emerged as some of the most promising strategies. This review first introduces the commonly utilized printing technologies, followed by discussion of the printable ink formulations and flexible substrates to ensure reliable device fabrication and system integration. The advances of printable sensors for body status monitoring are then discussed. Moreover, the integration of wireless data transmission via printable approaches is also presented. Finally, the challenges in achieving printable sensing devices and wireless integrated systems with competitive performances are considered, so as to realize their practical applications for personalized healthcare.


Assuntos
Inteligência Artificial , Dispositivos Eletrônicos Vestíveis , Humanos , Tecnologia sem Fio , Impressão
8.
PLoS One ; 19(3): e0300550, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38512925

RESUMO

The current electric vehicles (EVs) market is experiencing significant expansion, underscoring the need to address challenges associated with the limited driving range of EVs. A primary focus in this context is the improvement of the wireless charging process. To contribute to this research area, this study introduces a circular spiral coil design that incorporates transceiver coils. First, an in-depth analysis is conducted using Ansys Maxwell software to assess the effectiveness of the proposed solution through the magnetic field distribution, inductance properties, and mutual inductance between receiver and transmitter coils. In the next step, a direct shielding technique is applied, integrating a ferrite core bar to reduce power leakage and enhance power transmission efficiency. The ferrite magnetic shielding guides magnetic field lines, resulting in a significant reduction in flux leakage and improved power transmission. Lastly, a magnetic resonance series (SS) compensation wireless system is developed to achieve high coupling efficiency and superior performance. The system's effectiveness is evaluated through co-simulation using Ansys Simplorer software. The results confirm the effectiveness of the proposed solution, showing its ability to transmit 3.6 kilowatts with a success rate approaching 99%. This contribution significantly advances the development of wireless charging systems for electric vehicles, addressing concerns and promoting global adoption.


Assuntos
Fontes de Energia Elétrica , Tecnologia sem Fio , Eletricidade , Compostos Férricos
9.
PLoS One ; 19(3): e0300650, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38527025

RESUMO

As the demand for high-bandwidth Internet connections continues to surge, industries are exploring innovative ways to harness this connectivity, and smart agriculture stands at the forefront of this evolution. In this paper, we delve into the challenges faced by Internet Service Providers (ISPs) in efficiently managing bandwidth and traffic within their networks. We propose a synergy between two pivotal technologies, Multi-Protocol Label Switching-Traffic Engineering (MPLS-TE) and Diffserv Quality of Service (Diffserv-QoS), which have implications beyond traditional networks and resonate strongly with the realm of smart agriculture. The increasing adoption of technology in agriculture relies heavily on real-time data, remote monitoring, and automated processes. This dynamic nature requires robust and reliable high-bandwidth connections to facilitate data flow between sensors, devices, and central management systems. By optimizing bandwidth utilization through MPLS-TE and implementing traffic control mechanisms with Diffserv-QoS, ISPs can create a resilient network foundation for smart agriculture applications. The integration of MPLS-TE and Diffserv-QoS has resulted in significant enhancements in throughput and a considerable reduction in Jitter. Employment of the IPv4 header has demonstrated impressive outcomes, achieving a throughput of 5.83 Mbps and reducing Jitter to 3 msec.


Assuntos
Algoritmos , Redes de Comunicação de Computadores , Simulação por Computador , Tecnologia sem Fio , Agricultura
10.
Nature ; 627(8002): 174-181, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38355804

RESUMO

Social interactions represent a ubiquitous aspect of our everyday life that we acquire by interpreting and responding to visual cues from conspecifics1. However, despite the general acceptance of this view, how visual information is used to guide the decision to cooperate is unknown. Here, we wirelessly recorded the spiking activity of populations of neurons in the visual and prefrontal cortex in conjunction with wireless recordings of oculomotor events while freely moving macaques engaged in social cooperation. As animals learned to cooperate, visual and executive areas refined the representation of social variables, such as the conspecific or reward, by distributing socially relevant information among neurons in each area. Decoding population activity showed that viewing social cues influences the decision to cooperate. Learning social events increased coordinated spiking between visual and prefrontal cortical neurons, which was associated with improved accuracy of neural populations to encode social cues and the decision to cooperate. These results indicate that the visual-frontal cortical network prioritizes relevant sensory information to facilitate learning social interactions while freely moving macaques interact in a naturalistic environment.


Assuntos
Macaca , Córtex Pré-Frontal , Aprendizado Social , Córtex Visual , Animais , Potenciais de Ação , Comportamento Cooperativo , Sinais (Psicologia) , Tomada de Decisões/fisiologia , Função Executiva/fisiologia , Macaca/fisiologia , Neurônios/fisiologia , Estimulação Luminosa , Córtex Pré-Frontal/citologia , Córtex Pré-Frontal/fisiologia , Recompensa , Aprendizado Social/fisiologia , Córtex Visual/citologia , Córtex Visual/fisiologia , Tecnologia sem Fio
11.
IEEE Trans Nanobioscience ; 23(2): 355-367, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38349839

RESUMO

Advancements in biotechnology and molecular communication have enabled the utilization of nanomachines in Wireless Body Area Networks (WBAN2) for applications such as drug delivery, cancer detection, and emergency rescue services. To study these networks effectively, it is essential to develop an ideal propagation model that includes the channel response between each pair of in-range nanomachines and accounts for the interference received at each receiver node. In this paper, we employ an advection-diffusion equation to obtain a deterministic channel matrix through a vascular WBAN2. Additionally, the closed forms of inter-symbol interference (ISI) and co-channel interference (CCI) are derived for both full duplex (FDX) and half duplex transmission (HDX) modes. By applying these deterministic formulations, we then present the stochastic equivalents of the ideal channel model and interference to provide an innovative communication model by simultaneously incorporating CCI, ISI, and background noise. Finally, we evaluate the results with numerous experiments and use signal-to-interference-plus-noise ratio (SINR) and capacity as metrics.


Assuntos
Biotecnologia , Comunicação , Difusão , Sistemas de Liberação de Medicamentos , Redes de Comunicação de Computadores , Tecnologia sem Fio
12.
PLoS One ; 19(2): e0296392, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38408070

RESUMO

The quest for energy efficiency (EE) in multi-tier Heterogeneous Networks (HetNets) is observed within the context of surging high-speed data demands and the rapid proliferation of wireless devices. The analysis of existing literature underscores the need for more comprehensive strategies to realize genuinely energy-efficient HetNets. This research work contributes significantly by employing a systematic methodology, utilizing This model facilitates the assessment of network performance by considering the spatial distribution of network elements. The stochastic nature of the PPP allows for a realistic representation of the random spatial deployment of base stations and users in multi-tier HetNets. Additionally, an analytical framework for Quality of Service (QoS) provision based on D-DOSS simplifies the understanding of user-base station relationships and offers essential performance metrics. Moreover, an optimization problem formulation, considering coverage, energy maximization, and delay minimization constraints, aims to strike a balance between key network attributes. This research not only addresses crucial challenges in creating EE HetNets but also lays a foundation for future advancements in wireless network design, operation, and management, ultimately benefiting network operators and end-users alike amidst the growing demand for high-speed data and the increasing prevalence of wireless devices. The proposed D-DOSS approach not only offers insights for the systematic design and analysis of EE HetNets but also systematically outperforms other state-of-the-art techniques presented. The improvement in energy efficiency systematically ranges from 67% (min side) to 98% (max side), systematically demonstrating the effectiveness of the proposed strategy in achieving higher energy efficiency compared to existing strategies. This systematic research work establishes a strong foundation for the systematic evolution of energy-efficient HetNets. The systematic methodology employed ensures a comprehensive understanding of the complex interplay of network dynamics and user requirements in a multi-tiered environment.


Assuntos
Redes de Comunicação de Computadores , Tecnologia sem Fio , Simulação por Computador , Conservação de Recursos Energéticos , Fenômenos Físicos
13.
PLoS One ; 19(2): e0299396, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38394126

RESUMO

With more and more demand from devices to use wireless communication networks, there has been an increased interest in resource sharing among operators, to give a better link quality. However, in the analysis of the benefits of resource sharing among these operators, the important factor of co-location is often overlooked. Indeed, often in wireless communication networks, different operators co-locate: they place their base stations at the same locations due to cost efficiency. We therefore use stochastic geometry to investigate the effect of co-location on the benefits of resource sharing. We develop an intricate relation between the co-location factor and the optimal radius to operate the network, which shows that indeed co-location is an important factor to take into account. We also investigate the limiting behavior of the expected gains of sharing, and find that for unequal operators, sharing may not always be beneficial when taking co-location into account.


Assuntos
Eficiência , Tecnologia sem Fio
14.
Chem Rev ; 124(5): 2205-2280, 2024 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-38382030

RESUMO

Advances in soft materials, miniaturized electronics, sensors, stimulators, radios, and battery-free power supplies are resulting in a new generation of fully implantable organ interfaces that leverage volumetric reduction and soft mechanics by eliminating electrochemical power storage. This device class offers the ability to provide high-fidelity readouts of physiological processes, enables stimulation, and allows control over organs to realize new therapeutic and diagnostic paradigms. Driven by seamless integration with connected infrastructure, these devices enable personalized digital medicine. Key to advances are carefully designed material, electrophysical, electrochemical, and electromagnetic systems that form implantables with mechanical properties closely matched to the target organ to deliver functionality that supports high-fidelity sensors and stimulators. The elimination of electrochemical power supplies enables control over device operation, anywhere from acute, to lifetimes matching the target subject with physical dimensions that supports imperceptible operation. This review provides a comprehensive overview of the basic building blocks of battery-free organ interfaces and related topics such as implantation, delivery, sterilization, and user acceptance. State of the art examples categorized by organ system and an outlook of interconnection and advanced strategies for computation leveraging the consistent power influx to elevate functionality of this device class over current battery-powered strategies is highlighted.


Assuntos
Fontes de Energia Elétrica , Tecnologia sem Fio , Próteses e Implantes , Eletrônica
15.
Sci Rep ; 14(1): 3422, 2024 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-38341483

RESUMO

Biosensor nodes of a wireless body area network (WBAN) transmit physiological parameter data to a central hub node, spending a substantial portion of their energy. Therefore, it is crucial to determine an optimal location for hub placement to minimize node energy consumption in data transmission. Existing methods determine the optimal hub location by sequentially placing the hub at multiple random locations within the WBAN. Performance measures like link reliability or overall node energy consumption in data transmission are estimated for each hub location. The best-performing location is finally selected for hub placement. Such methods are time-consuming. Moreover, the involvement of other nodes in the process of hub placement results in an undesirable loss of network energy. This paper shows the whale optimization algorithm (WOA)-based hub placement scheme. This scheme directly gives the best location for the hub in the least amount of time and with the least amount of help from other nodes. The presented scheme incorporates a population of candidate solutions called "whale search agents". These agents carry out the iterative steps of encircling the prey (identifying the best candidate solution), bubble-net feeding (exploitation phase), and random prey search (exploration phase). The WOA-based model eventually converges into an optimized solution that determines the optimal location for hub placement. The resultant hub location minimizes the overall amount of energy consumed by the WBAN nodes for data transmission, which ultimately results in an elongated lifespan of WBAN operation. The results show that the proposed WOA-based hub placement scheme outperforms various state-of-the-art related WBAN protocols by achieving a network lifetime of 8937 data transmission rounds with 93.8% network throughput and 9.74 ms network latency.


Assuntos
Técnicas Biossensoriais , Baleias , Animais , Reprodutibilidade dos Testes , Tecnologia sem Fio , Redes de Comunicação de Computadores
16.
PLoS One ; 19(2): e0297810, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38358986

RESUMO

Ultra-reliable low-latency communication (URLLC) is a key technology in future wireless communications, and finite blocklength (FBL) coding is the core of the URLLC. In this paper, FBL coding schemes for the wireless multi-antenna channels are proposed, which are based on the classical Schalkwijk-Kailath scheme for the point-to-point additive white Gaussian noise channel with noiseless feedback. Simulation examples show that the proposed feedback-based schemes almost approach the corresponding channel capacities.


Assuntos
Redes de Comunicação de Computadores , Tecnologia sem Fio , Retroalimentação , Simulação por Computador , Comunicação
17.
Sensors (Basel) ; 24(4)2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38400327

RESUMO

The design and experimental verification of a deeply implanted conformal printed antenna is presented. The hip implant acts as the ground plane for a coaxial-cable-fed trapezoidal radiator designed to transmit biological signals collected within the body by proper biosensors. The arrangement, consisting of a metallic (or equivalent) hip implant, bio-compatible gypsum-based dielectric, and conformal radiator, was tested when the hosting 3D-printed plastic bone was immersed in tissue-like liquid contained in a plastic bucket. The dimensions of the set-up are similar to a human leg. Matching and radiation characteristics are presented in the industrial, scientific, and medical (ISM) frequency band (2.4-2.5 GHz), showing the feasibility of the proposed arrangement.


Assuntos
Telemetria , Tecnologia sem Fio , Humanos , Próteses e Implantes
18.
Biosens Bioelectron ; 252: 116083, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38387231

RESUMO

Energy supply and sensor response acquisition can be performed wirelessly, enabling biosensors as Internet of Thing (IoT) tools by linking wireless power supply and electrochemical sensors. Here, we used the electromagnetic induction method to clarify the conditions under which electrochemiluminescence is induced by a simple potential modulation circuit without an integrated circuit on the electrode chip that receives the power. Initially, the potential waveform obtained in a circuit with inductance and capacitance components that resonate with the transmission frequency and a diode for rectification was investigated to clarify the conditions inducing an electrochemiluminescence reaction at the printed electrode. A high-sensitivity complementary metal-oxide semiconductor camera built into the smartphone wirelessly detected the luminescence generated on the electrode chip. The images were quantitatively evaluated using open-source image analysis software which determine the sensitivity of detecting hydrogen peroxide. Glucose oxidase (GOD) encapsulated in a matrix of chitosan polymers and photocrosslinkable polymers was immobilized on a mass-producible and inexpensive printed electrode to maintain high activity. The immobilized membrane suppressed luminescence when immobilized on the working electrode; therefore, the enzyme was immobilized on the counter electrode for glucose measurement over a wide concentration. Thus, luminol electrochemiluminescence was induced on the electrode chip by wireless power supply from a smartphone. Human serum and artificial sweat samples were tested and indicated possibility for actual applications. In this way a fully wireless biosensor was developed with potential as an IoT biosensor.


Assuntos
Técnicas Biossensoriais , Smartphone , Humanos , Medições Luminescentes/métodos , Técnicas Biossensoriais/métodos , Glucose Oxidase , Polímeros , Tecnologia sem Fio
19.
Nature ; 627(8002): 80-87, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38418888

RESUMO

Integrated microwave photonics (MWP) is an intriguing technology for the generation, transmission and manipulation of microwave signals in chip-scale optical systems1,2. In particular, ultrafast processing of analogue signals in the optical domain with high fidelity and low latency could enable a variety of applications such as MWP filters3-5, microwave signal processing6-9 and image recognition10,11. An ideal integrated MWP processing platform should have both an efficient and high-speed electro-optic modulation block to faithfully perform microwave-optic conversion at low power and also a low-loss functional photonic network to implement various signal-processing tasks. Moreover, large-scale, low-cost manufacturability is required to monolithically integrate the two building blocks on the same chip. Here we demonstrate such an integrated MWP processing engine based on a 4 inch wafer-scale thin-film lithium niobate platform. It can perform multipurpose tasks with processing bandwidths of up to 67 GHz at complementary metal-oxide-semiconductor (CMOS)-compatible voltages. We achieve ultrafast analogue computation, namely temporal integration and differentiation, at sampling rates of up to 256 giga samples per second, and deploy these functions to showcase three proof-of-concept applications: solving ordinary differential equations, generating ultra-wideband signals and detecting edges in images. We further leverage the image edge detector to realize a photonic-assisted image segmentation model that can effectively outline the boundaries of melanoma lesion in medical diagnostic images. Our ultrafast lithium niobate MWP engine could provide compact, low-latency and cost-effective solutions for future wireless communications, high-resolution radar and photonic artificial intelligence.


Assuntos
Micro-Ondas , Nióbio , Óptica e Fotônica , Óxidos , Fótons , Inteligência Artificial , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Melanoma/diagnóstico por imagem , Melanoma/patologia , Óptica e Fotônica/instrumentação , Óptica e Fotônica/métodos , Radar , Tecnologia sem Fio , Humanos
20.
J Neuroeng Rehabil ; 21(1): 4, 2024 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172975

RESUMO

BACKGROUND: Recently we reported the design and evaluation of floating semi-implantable devices that receive power from and bidirectionally communicate with an external system using coupling by volume conduction. The approach, of which the semi-implantable devices are proof-of-concept prototypes, may overcome some limitations presented by existing neuroprostheses, especially those related to implant size and deployment, as the implants avoid bulky components and can be developed as threadlike devices. Here, it is reported the first-in-human acute demonstration of these devices for electromyography (EMG) sensing and electrical stimulation. METHODS: A proof-of-concept device, consisting of implantable thin-film electrodes and a nonimplantable miniature electronic circuit connected to them, was deployed in the upper or lower limb of six healthy participants. Two external electrodes were strapped around the limb and were connected to the external system which delivered high frequency current bursts. Within these bursts, 13 commands were modulated to communicate with the implant. RESULTS: Four devices were deployed in the biceps brachii and the gastrocnemius medialis muscles, and the external system was able to power and communicate with them. Limitations regarding insertion and communication speed are reported. Sensing and stimulation parameters were configured from the external system. In one participant, electrical stimulation and EMG acquisition assays were performed, demonstrating the feasibility of the approach to power and communicate with the floating device. CONCLUSIONS: This is the first-in-human demonstration of EMG sensors and electrical stimulators powered and operated by volume conduction. These proof-of-concept devices can be miniaturized using current microelectronic technologies, enabling fully implantable networked neuroprosthetics.


Assuntos
Terapia por Estimulação Elétrica , Músculo Esquelético , Humanos , Eletromiografia , Eletrodos Implantados , Músculo Esquelético/fisiologia , Extremidade Inferior , Tecnologia sem Fio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...